2022-12
22
IDM-Z1-264-M-2D-J1-BT-N-N0, IDM-Z1-164-M-1D-J1-BT-P-N0
Commissioning
5.2 Pinout of Supply Module with RS-232 or USB
Supplying the base station according to system structure 2 via
connector - plug/coupling.
The terminal assignment is located under the unscrewable opening on the front of the supply
module.
Changes to the pinout may only be carried out by trained and qualified personnel.
Connection of the base station to the supply module RS-232 or USB via
connector - plug/coupling
The terminal assignment is located under the unscrewable opening on the front of the supply
module.
(1) Ex e terminal compartment to connect the power supply and the data line
(2) Ex i terminal compartment to connect the consumers (base station/scanner)
Figure 5.12 Supply module terminal compartment
External connection lines:
The Bluetooth® handheld scanner, the base station, and the supply module may be connected
and used in explosion-hazardous areas. The current rating of the connection line must be
observed.
Danger!
Do not open the housing in the explosion-hazardous area
Before the device is put into operation in explosion-hazardous areas, it must be ensured that
the housing is completely closed again and screwed on properly.
Data lines
USB: 0.2 – 2.5 mm
2
, 4-core or
RS-232: 0.2 – 2.5 mm
2
3-core
Supply line
0.2 – 2.5 mm
2
3-wire
(see accessories in the appendix)