IDM-Z1-264-M-2D-J1-BT-N-N0, IDM-Z1-164-M-1D-J1-BT-P-N0
Commissioning
5.3 Base connection line RS-232
Assignment of pre-installed base connection cable to supply module (RS-232)
Direct connection of the base station without a plug/coupling to the
supply module with RS-232 interface
The base station can be connected directly to the supply module without using the blue base
connection cable.
The assignment of the serial base station cable CBL-IDM-x61* is outlined in the following table.
Figure 5.15 Connection layout
Assignment of connection cable CBL-IDM-x61* to supply module (RS-232)
Assignment of pre-assembled connec-
tion coupling
Supply module terminal compartment
Pin Core designation Designation Number
3 3 RxD X9
GND X10
PE X11
2 2 GND X12
1 1 +UB X13
Cordset assignment Supply module terminal compartment
RJ50 pinout Strand color Designation Assignment
6 White TxD X9
X10
X11
4 Brown GND X12
7 Ye l l o w +UB X13
Note
Information relating to programming from the SICK AG manual (www.SICK.com) is required for
the complete commissioning of the handheld scanner.