Before using your window air
conditioner, please read this manual
carefully and keep it for future
reference, along with your receipt.
Your Source for Home Comfort
WINDOW
AIR CONDITIONER
USER MANUAL
17,700, 18,500, 25,000 & 28,000 BTU
FOR MODELS:
3PAHP18002
with 11,200 BTU heat pump
3PACH18000
with 16,000 BTU electric heater
3PACH25000
with 16,000 BTU electric heater
3PNC28000

Questions and Answers

  • F
    fowlermichelleAug 22, 2025
    What to do if my Perfect Aire 3PAHP18002 has water puddles inside?
    • H
      Heidi BoyleAug 22, 2025
      If water is puddling inside your Perfect Aire unit or coming into the room, adjust the slope of the unit, so it drains downward toward the exterior of the home, referring to the installation instructions. Also, ensure that there is no debris blocking the drainage area of the unit.
  • C
    Christopher GomezAug 25, 2025
    What to do if my Perfect Aire Air Conditioner unit will not turn on?
    • H
      Holly RichardsAug 25, 2025
      If your Perfect Aire unit will not turn on, reset the circuit breaker, ensuring that the breaker isn't overloaded with too many items. Check the plug connection and ensure the outlet switch is turned ‘on’ if applicable. Try plugging the unit into another outlet. As a last resort, unplug the unit for at least 5 minutes and follow the reset instructions on the plug.
  • M
    Michael GrimesAug 28, 2025
    What to do if my Perfect Aire Air Conditioner will not turn on?
    • W
      William LeeAug 28, 2025
      If your Perfect Aire air conditioner won't turn on, first reset the circuit breaker, ensuring not too many devices are on the same breaker. Check the plug connection and ensure the outlet switch is 'on' if applicable. Try plugging the unit into a different outlet. Unplug the unit for at least 5 minutes and follow the reset instructions on the plug.
  • A
    Amy MendozaAug 30, 2025
    What to do if water puddles inside my Perfect Aire Air Conditioner?
    • J
      Jason StanleyAug 30, 2025
      If water is puddling inside your Perfect Aire unit or coming into the room, adjust the unit's slope so it drains downward toward the exterior of the house. Also, make sure that there is no debris blocking the drainage area of the unit.
  • B
    barry36Sep 1, 2025
    Why is my Perfect Aire Air Conditioner dripping water outside?
    • A
      Ashley RobbinsSep 1, 2025
      The unit is removing a large quantity of moisture from a humid room. This is normal during excessively humid days.
  • D
    Douglas VangSep 3, 2025
    Why is my Perfect Aire Air Conditioner cooling but the room is too warm and ice is forming?
    • K
      Kaitlyn MunozSep 3, 2025
      If your Perfect Aire air conditioner is cooling, but the room is too warm and ice is forming on the cooling coil, it could be due to several reasons. If the outdoor temperature is below 64ºF (18ºC), set the unit to Fan Only mode to defrost the coil. Also, the air filter may be dirty, so clean it. If the thermostat is set too cold for nighttime cooling, defrost the coil by setting it to Fan Only mode and then increase the temperature setting.
  • J
    Jacob RobertsSep 5, 2025
    How to fix a noisy Perfect Aire 3PAHP18002 Air Conditioner?
    • M
      Morgan JohnstonSep 5, 2025
      If your Perfect Aire air conditioner is making unusual noises, check to ensure the unit is free from debris like leaves or sticks and that nothing is obstructing it. Inspect the fan blade for cracks or chips. Make sure the unit is properly and securely mounted inside the window or wall. Also, clean the air filter.
  • P
    Pamela GutierrezSep 7, 2025
    Why does my Perfect Aire 3PAHP18002 cycle on and off too frequently?
    • C
      Charles ShermanSep 7, 2025
      If your Perfect Aire air conditioner is cycling on and off too frequently or not enough, ensure the unit is appropriately sized for the room. Remove the grille and make sure the temperature sensor is not too close to the coils; carefully straighten the tube if needed. Ensure nothing is blocking the grille or side vents and that there is no dirt or debris inside the unit or on the filter.
  • W
    watersdavidSep 9, 2025
    What causes my Perfect Aire 3PAHP18002 to blow fuses?
    • L
      Lisa ThomasSep 9, 2025
      If your Perfect Aire unit blows fuses or pops the circuit breaker, ensure there are enough available amps on the circuit for the air conditioner. Large units operating on 230v will require a dedicated 20 or 30 amp circuit.
  • M
    Mr. Carl BrownSep 12, 2025
    Why does Perfect Aire Air Conditioner Remote Sensing deactivate too soon?
    • M
      Mitchell GardnerSep 12, 2025
      If the Remote Sensing / Follow Me feature on your Perfect Aire unit is deactivating prematurely, make sure the remote control is located within 20 ft and a 180º radius of the front of the unit. Also, ensure that there are no obstructions blocking the remote control signal.

Perfect Aire 3PAHP18002 Specifications

General IconGeneral
BrandPerfect Aire
Model Number3PAHP18002
TypePortable Air Conditioner
Cooling Capacity (BTU)18000
Power Supply115V/60Hz
Amps15
Power Cord Length (ft)6
Fan Speeds3
Noise Level (dBA)54
RefrigerantR410A
Exhaust Hose Diameter (inches)5.9
Window Kit IncludedYes
Remote ControlYes
Timer24-Hour
Operating ModesCool, Fan, Dry