Electrical Diagram
PKD24B PARTS MANUAL Rev. 11.09 Page 11
4.2. Quick service guide
MODELS: L-1X, L-1X16 UNDER COUNTER
Delimer switch in delime position
Wash Pump motor will not shut off
Replace switch, P/N 00475.30
Faulty manual drain switch
Replace switch, P/N 03406.62
Replace contactor, P/N 00404.82
Faulty #1 micro switch (start/stop)
Replace switch, P/N 00411.00
Replace switch, P/N 03470.01
Replace switch, P/N 00411.00
Low water level inside machine
Add water to tank to activate float switch, adjust
water cam on timer
Sustainer heater not working
Replace switch, P/N 13463.10
Replace relay, P/N 00631.00
Faulty #3 micro switch (drain)
Replace switch, P/N 00411.00
Replace drain valve, P/N 04103.00
Faulty #3 micro switch (drain)
Replace switch, P/N 00411.00
Clogged or defective drain valve
Clean and/ or replace drain valve, P/N 04103.00
Debris in water Solenoid Valve
Clean and replace valve diaphragm, P/N
00707.00
Water leaks out of Vacuum Breaker
Dirty or defective vacuum breaker kit
assy
Clean or replace internal parts, P/N 03623.00
Replace check valve, P/N 00715.00
Male/ female plug on the back of control
drawer is loose
Wash Pump motor not running
Replace reed switch, P/N 00557.55
Replace switch, P/N 00411.00
Replace contactor, P/N 00404.82
Replace switch, P/N 03470.01
Replace switch, P/N 00411.00
Replace motor assembly, P/N 00501.00
Replace switch, P/N 00411.00
Debris inside water solenoid valve or
Faulty valve
Clean and replace valve diaphragm, P/N
00707.00
Faulty water solenoid coil
Replace solenoid coil, P/N 00738.10
Delimer switch in wrong position
Switch to
NORMAL
position
Sanitizer pump does not run
Replace switch, P/N 00411.00
Faulty sanitizer pump motor
Replace motor, P/N 00416.00