Translation of the
Original Operating Instructions
perma
PRO 250 / 500
PRO C 250 / 500
PRO / PRO C LINE 250 / 500
PRO MP-6 Distributor
PRO / PRO C MP-2
The Expert in Lubrications Solutions

Table of Contents

Other manuals for Perma PRO C 250

Questions and Answers

  • R
    richard94Aug 7, 2025
    What to do if my Perma Lubrication system displays an error at a lubrication point?
    • V
      Victoria McphersonAug 8, 2025
      If your Perma Lubrication system displays an error at the lubrication point, it is likely due to excess motor current caused by a blockage at the displayed outlet. The solution is to clear the blockage and then acknowledge the fault by pushing and holding down the ON/ OFF/SELECT button.
  • M
    Matthew LongAug 12, 2025
    What to do if my Perma Lubrication system has been switched off?
    • D
      David GoodwinAug 12, 2025
      Your Perma Lubrication system might be switched off due to several reasons. One potential cause is excess motor current in the perma MP-6. If this is the case, replace the perma MP-6 distributor. Other possible causes include incorrectly recognized distributor outlets, in which case you should replace the distributor. A timeout while activating the distributor or a damaged connection cable could also be the reason; in these cases, replace the distributor or the connection cable, respectively.
  • D
    Deborah WestAug 17, 2025
    Why has my Perma Lubrication system been switched off?
    • A
      Alexander NelsonAug 17, 2025
      The Perma Lubrication system might have been switched off because of excess motor current of the lubricator motor due to a blocked outlet or an empty battery set. Clear the blockage and acknowledge the fault by pushing and holding down the ON/ OFF/SELECT button. If the battery set is empty, insert a new battery set and use a full PRO LC unit. Another reason for this issue can be a defective drive mechanism. In this case, exchange the drive unit.
  • A
    Amanda MorganAug 22, 2025
    What to do if no power is supplied to my Perma Lubrication system from the battery?
    • B
      Brandy TrevinoAug 22, 2025
      If no power is being supplied to your Perma Lubrication system from the battery, the cause is likely that no battery is inserted or the battery set is empty. To resolve this, insert a new battery set and use a full PRO LC unit.
  • S
    Sandra RobertsAug 28, 2025
    What to do if the Perma Lubrication system does not detect the PRO LC unit?
    • L
      Lee RodriguezAug 28, 2025
      If the Perma Lubrication system does not detect the PRO LC unit, ensure that a PRO LC unit is installed. If it is not, install an PRO LC unit.
  • J
    Joyce LangSep 1, 2025
    What to do if the Perma Lubrication system outlet configuration is missing?
    • C
      Catherine GreenSep 2, 2025
      If the outlet configuration is missing in your Perma Lubrication system, it is probably because the outlets were not activated. To fix this, activate the desired outlets.