Phantom Ultrahigh-speed Camera Manual
Remote port (for Phantom RCU)
5-pin Fischer part # S103.A054
Phantom vxx12
Remote Connector
PIN NOMENCLATURE / FUNCTION
1 +24VDC
2 PNG / The power input and the acquisition control sig-
nals are isolated from the camera system ground. This
isolation is designed to avoid system ground loops only,
and should not be subject to high voltages.
3 XRXD / Receive Data (RS-232); +5V maximum, normally
limited to 50 feet (16 meters).
4 XTXD / Transmit Data (RS-232); +5V maximum, normally
limited to 50 feet (16 meters).
5 IOGND2 / RS232 Ground - All the serial ports are not
isolated (referred to system ground). As such, they
should only be connected to properly earthed equipment.
PIN NOMENCLATURE / FUNCTION
1 +20 - 28 Volts DC
2 CHGND / Chassis Ground
3 GND / Power Ground
Power ports
3-pin Fischer part # SS 104Z040-80
Phantom vxx12 Power Connector
(Primary / Battery Backup)