19” LCD Color Monitor 190B7
116
B_min
X 100% >75%
B_max
Where B_max =Maximum brightness
B_min = Minimum brightness
4.5 Check Cross talk (S)
Apply Pattern 2. Set contrast and brightness at 100 %.
Measure YA. Then output Pattern 3 and measure YB.
the cross talk value :
ABS (YA - YB)
⎯⎯⎯⎯⎯⎯⎯⎯⎯ X 100% < 1.5 %
YA
4.6 White color adjustment
There are three factory preset white color 9300K, 6500K, sRGB.
Apply full gray64 pattern, with brightness in 100 % position and the contrast control at 50 % position.
The 1931 CIE Chromaticity (color triangle) diagram (x,y) coordinate for the screen center should be:
Product spec.
9300K CIE coordinates X = 0.283 ± 0.02 Y = 0.297 ± 0.02
6500K/ sRGB CIE coordinates X = 0.313 ± 0.02 Y = 0.329 ± 0.02
sRGB CIE coordinates X = 0.313 ± 0.02 Y = 0.329 ± 0.02
Production alignment spec.
9300K CIE coordinates X = 0.283 ± 0.005 Y = 0.297 ± 0.005
6500K/ sRGB CIE coordinates X = 0.313 ± 0.005 Y = 0.329 ± 0.005
sRGB CIE coordinates X = 0.313 ± 0.005 Y = 0.329 ± 0.005
Quality Inspection spec.
9300K CIE coordinates X = 0.283 ± 0.015 Y = 0.297 ± 0.015
6500K/ sRGB CIE coordinates X = 0.313 ± 0.015 Y = 0.329 ± 0.015
sRGB CIE coordinates X = 0.313 ± 0.015 Y = 0.329 ± 0.015
5. Mechanical characteristics
5.1 Cosmetic - Philips ID
5.2 Mechanical data files - ProE files required
5.3 Location of Philips logo - Per Philips make-up sheet
5.4 Gap between panel and front bezel < 0.8 mm
5.5 Location of Control icons - Per Philips Graphic sheet
5.6 Color for resin/paint - Per Philips make-up sheet