EasyManua.ls Logo

Philips 190B7 - Check Cross Talk (S); Mechanical Characteristics; White Color Adjustment

Philips 190B7
121 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
19 LCD Color Monitor 190B7
116
B_min
X 100% >75%
B_max
Where B_max =Maximum brightness
B_min = Minimum brightness
4.5 Check Cross talk (S)
Apply Pattern 2. Set contrast and brightness at 100 %.
Measure YA. Then output Pattern 3 and measure YB.
the cross talk value :
ABS (YA - YB)
⎯⎯⎯⎯⎯⎯⎯⎯⎯ X 100% < 1.5 %
YA
4.6 White color adjustment
There are three factory preset white color 9300K, 6500K, sRGB.
Apply full gray64 pattern, with brightness in 100 % position and the contrast control at 50 % position.
The 1931 CIE Chromaticity (color triangle) diagram (x,y) coordinate for the screen center should be:
Product spec.
9300K CIE coordinates X = 0.283 ± 0.02 Y = 0.297 ± 0.02
6500K/ sRGB CIE coordinates X = 0.313 ± 0.02 Y = 0.329 ± 0.02
sRGB CIE coordinates X = 0.313 ± 0.02 Y = 0.329 ± 0.02
Production alignment spec.
9300K CIE coordinates X = 0.283 ± 0.005 Y = 0.297 ± 0.005
6500K/ sRGB CIE coordinates X = 0.313 ± 0.005 Y = 0.329 ± 0.005
sRGB CIE coordinates X = 0.313 ± 0.005 Y = 0.329 ± 0.005
Quality Inspection spec.
9300K CIE coordinates X = 0.283 ± 0.015 Y = 0.297 ± 0.015
6500K/ sRGB CIE coordinates X = 0.313 ± 0.015 Y = 0.329 ± 0.015
sRGB CIE coordinates X = 0.313 ± 0.015 Y = 0.329 ± 0.015
5. Mechanical characteristics
5.1 Cosmetic - Philips ID
5.2 Mechanical data files - ProE files required
5.3 Location of Philips logo - Per Philips make-up sheet
5.4 Gap between panel and front bezel < 0.8 mm
5.5 Location of Control icons - Per Philips Graphic sheet
5.6 Color for resin/paint - Per Philips make-up sheet