EasyManua.ls Logo

Philips 190B7 - Display Disturbances from External Environment; Display Disturbances to External Environment; Environmental Characteristics; Mean Time between Failures

Philips 190B7
121 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
19 LCD Color Monitor 190B7
118
Drop test
Cold Drop test (for design reference)
Un-package test
Sine vibration (operating)
Half sine shock test (non operation)
5.16 Pallet / Container loading
Transportation standards refer to TYE-M0002.
Air shipment - tbc
Sea container 20'(pallet/slip sheet) - tbc
Sea container 40'(pallet/slip sheet) - tbc
Sea container 40' High Cube (pallet/slip sheet) - tbc
Truck shipment- tbc
A. Air shipment
B. Container loading for other regions
C. Truck loading for other regions
6. Environmental characteristics
The following sections define the interference and susceptibility condition limits that might occur
between external environment and the display device.
6.1 Susceptibility of display to external environment
Operating
- Temperature : 0 to 40 degree C
- Humidity : 80% max
- Altitude : 0-3658m
- Air pressure : 600-1100 mBAR
Storage
- Temperature : -20 to 60 degree C
- Humidity : 95% max
- Altitude : 0-12192m
- Air pressure : 300-1100 mBAR
Note: recommend at 5 to 35°C, Humidity less than 60 %
6.2 Transportation tests
Refer to 5.15.2
6.3 Display disturbances from external environment
According to IEC 801-2 for ESD disturbances
6.4 Display disturbances to external environment
7. Reliability
7.1 Mean Time Between Failures
System MTBF (Including the LCD panel and CCFL): 50,000 hrs
8. Quality assurance requirements
8.1 Acceptance test
According to MIL-STD-105D Control II level
AQL: 0.4 (major) 1.5 (minor)
(Please also refer to annual quality agreement)
Customer acceptance criteria: UAW0377/00

Table of Contents

Other manuals for Philips 190B7

Related product manuals