HUDSON 9
67
3.12 Hot-key definition
Item Key
Key Press
Time
OSD
Timeout
OSD Message
Monitor Controls
Lock
Menu
6 sec 5 sec
Monitor controls locked
Monitor controls unlockeddefault
Factory Mode [AUTO]+[Menu]+[Power]
DDC/CI On/OFF
for VISTA
[MENU]+[DOWN] 5 sec 5 sec
DDC/CI ON (default)
DDC/CI OFF
4. Visual characteristics
4.1 Test conditions
Unless otherwise specified, this specification is defined under the following conditions.
(1) Input signal: As defined in 3.3, 1366*768
non-interlaced mode (1366*768@60Hz 146.25MHz),
Signal sources must have 75 ohm output impedance..
(2) Luminance setting : controls to be set to 300 nits with
Full screen 100 % duty cycle white signal
(3) Warm up: more than 30 minutes after power on with signal supplied.
(4) Ambient light: 400 -- 600 lux.
(5) Ambient temperature: 20 ± 5 °C
4.2 Brightness
To follow Panel specification..
4.3 Image size
Actual display size: Refer to 2.1 LCD PANEL spec.
4.4 Brightness uniformity
Set contrast at 100% and turn the brightness to get average above 300 nits at centre of the
screen.
Apply the Fig 1; it should comply with the following formula:
B_min
X 100% >75% (Follow panel spec)
B_max
Where B_Max. =Maximum brightness, B_Min. = Minimum brightness
4.5 Check Cross talk (S)
Apply Pattern 2. Set contrast and brightness at 100 %.
Measure YA. Then output Pattern 3 and measure YB.
The cross talk value:
ABS (YA -YB)
⎯⎯⎯⎯⎯⎯⎯⎯⎯ X 100% < 1.5 %
YA

Table of Contents