Disassembly- and Reassembly advice
Now the Motor housing can be removed by
lifting: Grip on back side with one hand, with
other hand push down in the Dust chamber.
To replace the motor (37) and PCB (32):
The PCB is connected to the Motor with 2 wires
through the Motor housing.
Remove the Motor housing Cover by unclicking
the 3 clicks.
Watch out: Valve assy spring jumps out !
Remove the Motor rubber (38).
Pull the motor to the outside and remove the 2
wires X and Y connected to the PCB.
Now the motor and PCB can be replaced.
(see exploded view)
Reassembly
The Motor rubber needs to be replaced correctly,
safety valve can be replaced and afterwards the
Motor housing cover can be clicked on.
Replace Motorassy in the Lower housing.
Fix all the screws (E).
Replace the Cordwinder assy and reconnect de
2 wires to the PCB on the Motor housing.
First leed the cord through the Cord outlet, then
the Cordwinder assy can be replaced.
Keep the cable and plug in its original position!!!
Replace the Top housing and x all the screws
(B) and (C).
Now the Dustcover assy can be replaced by
using a screwdriver.
Remark: Safety valve cannot be supplied
separately, make sure that this can be re-used.