PHI 5000 LATTE GO / GO+ 03 OPERATING LOGIC
5/8
3.9. AquaClean water lter
e AquaClean lter is designed to reduce limescale deposits in the coee machine and provide ltered water to
preserve the aroma and avor of each cup of coee. By using a series of 8 AquaClean lters, there is no need to
descale the machine for 5000 cups (It depends both on the type of coee used, rinsing and cleaning programs).
We recommend installing the water lter AquaClean the rst use of the ma-
chine to the maximum before using 5 L of water. e machine display will indicate
when the lter needs to be replaced. e maximum limit is equivalent to 110 L of water.
e conditions related to the lter work environment (water, therefore, an active environment for bacteria
and microorganisms), require the replacement with a minimum frequency (we suggest 3 months from the
activation to ensure the best performance). e lter starts’ working from the time is lled with water and
continues working even with the machine o. It cannot be deactivated manually, as it must end its life cycle.
At the lter activation the display shows the icon with the percentage of use:
- Initially 100% then decreasing.
When the autonomy of the current lter becomes less than 8 L of water the display
shows:
- e icon ashing slowly. It means 10%.
When the autonomy of the current lter becomes less than 2 L of water the display
shows
- e icon ashing quickly. It means 0%.
Aer a maximum of 110 L of water supplied the ashing light turn o and the
machine needs to be descaled.
e water tank of all PHI5000 models is designed to t only with the AquaClean lter.
3.10. Descaling request
Descaling frequency in AQUACLEAN
The rst activation must make before you've paid up to 5000ml products because mind thinks as
if he had the lter
Hardness
Filter num-
ber
Percentual on
display 10%
the icon ashes
slowly. (encourage
the consumer to
buy the lter)
Percentual on
display 0% the
icon ashes
quickly. (tell
the consumer
to change the
lter)
MAX Quantity
water, the icon
turns off. (re-
place lter)
Indifferent
From 1/8 to
7/8
8050ml 2000ml
62500ml
75000ml only OTC
Replace lter (you
can not turn off)
8/8 Descaling
If after descaling or after the use of a lter this is not reactivated , the machine recognizes the water
hardness setting and calculates as in the table below
Descaling cycle frequency
Hardness WATER HARDNESS Without water lter Not reactivating the lter
1 Soft (up to 7°dH) 240 litres (480,000 pulses) 210 litres (420,000 pulses)
2 Medium (7° - 14°dH) 120 litres (240,000 pulses) 105 litres (210,000 pulses)
3 Hard (15° - 21°dH) 60 litres (120,000 pulses) 52.5 litres (105,000 pulses)
4 Very hard (over 21°dH) 30 litres (60,000 pulses) 26.25 litres (52,500 pulses)
The default water hardness level is 4. Each litre of water corresponds to approximately 2,000 pulses.