9EN
Filter reset
You can replace the lter even before lter replacement alert ( ) displays on the screen. After
replacing a lter, you need to reset the lter lifetime counter manually.
1 Press the power button to turn on the appliance�
2 Within 10 seconds after power on, press and hold the mode switch button for 5 seconds to
reset the lter lifetime counter.
6 Storage
1 Turn o the air purier and unplug from the power socket.
2 Clean the air purier, air quality sensor and the surface of the lter (see the chapter “Cleaning”).
3 Let all parts air dry thoroughly before storing.
4 Wrap the lter in air tight plastic bags.
5 Store the air purier, lter in a cool, dry location.
6 Always thoroughly wash hands after handling a lter.
7 Troubleshooting
This chapter summarizes the most common problems you could encounter with the appliance. If you
are unable to solve the problem with the information below, contact the Consumer Care Center in your
country�
Problem Possible solution
The appliance does not
work even though it is
plugged in�
•
The lter replacement alert is ashing but you have not replaced the
corresponding lter. As a result, the appliance is now locked. In this case,
replace the lter and reset the lter lifetime counter.
The airow that comes
out of the air outlet is
signicantly weaker
than before�
•
The surface of the lter is dirty. Clean the surface of the lter (see the
chapter “Cleaning”).
The air quality does not
improve, even though
the appliance has been
operating for a long
time�
•
Check if the packing material is removed from the lter.
•
Make sure that the lter is properly installed.
•
The air quality sensor is dirty or wet. Clean the air quality sensor (See the
chapter “Cleaning”).
•
Room size is large or the outdoor air quality is poor.
For optimum purication performance, please close the doors and
windows when operating the air purier.
•
There are indoor pollution resources� For instances, smoking, cooking,
incense�
•
Filter reaches the end of life. Replace the lter with a new one.