o
MECHANTSM
ADJUSTMENTS
(HEAD
pOStTtON
ADJUSTMENT)
o
Disassembly
1.
Remove
the
2
screws
of
the arm on the
cassette
lid
ass'y.
(Ref.
No.4
@, @
on
page
4.)
Remove
the 3
screws of
the bottom cabinet
ass'y
and then,
take
out the bottom
cabinet
ass'y.
(Ref.
No. 1
on
page
3.)
Remove
the
LCD flexible
board
from
the
connector.
(JU02)
Remove
the
4
screws
of the
Rear
protector
retainer
and open
the center
frame.
Pull
the
cassette
lid
ass'y.
(Ref.
No.
2 @, @, No.
5
O
,
@
on
pages
3
and
4.)
Insert
the
small
(-)
screwdriver
into
a
clearance
between
the LCD retainer
(R)
flange
and
the
cassette holder in
the
mechanism
little
by
little,
and then
remove
a
pin
at
the
mechanism
side
(shown
on the
right figure).
Remove
a
pin
at
the
left
side as
well.
Connect
the connecter
(JU02)
with
the LCD
flexible
board which is removed
on
No.
3.
Press
the open detecting
switch
with
an
adhesive
tape
and
hold
the
power
"ON".
A
tape
is loading
without
any
interference
with
the cassette lid
ass'y.
Perform head
position
adjustment
after
disassembling
the
unit to the
point
shown on the
below.
2.
3.
4.
5.
LCD retainer
(R)
flange
6.
7.
8.
9.
Ceramic
screwdriver
(Head
alignment)
(HOZAN
D-2981,
+ No.
0)
Head
alignment
adjusting
screwdriver
(R220296)
o Name
of
adjusting
screw
Open
detect
switch
(Press
the
open detect
switch
with
an adhesive-tape)
@
Head height
adjusting
screw
(R)
Tape
guide (R)
Tape
guide
(L)
Head
height
adjusting
screw
(L)
PCS
79 274