Philips EP Series
Specication for the measurement of the coee products temperature
Before measuring the in-cup temperature make sure the following conditions will be met:
Conditions:
a) Water temperature in tank: °C (+/-°C).
b) Use a plastic cup (see picture ).
c) Use a digital thermometer (see picture ) (e.g. type K probe diameter max mm (see picture ).
d) The coee machine is tested without any change of parameters or calibrations, which may aect the
temperature of products, so the measurement of temperature must be done with machine in default factory
setting.
Procedure:
. Place the plastic cup under the dispensing spout. (picture )
. Dispense coee
. Measure the temperature immediately after coee has being dispensed, you need to nish the
measurement within seconds. The temperature in the cup is measured by placing the probe of the
thermometer in the cup near the bottom. Then stir the probe in the cup for to times and read out the
thermometer values during stirring. Hold the probe still in the center of the cup.
. Record the highest value.
Depending on the coee volume selected to measure, you would need to position the probe on several
height levels to measure the correct temperature in the plastic cup.
mm for gr - mm for gr - mm for gr (see Picture ).
Technical information
Espresso Coee Italy Q.ty 40 gr.
Temperature of 1st product 69°C ≤ 85°C
Temperature of 2nd product 72°C ≤ 85°C
Coee Q.ty 120 gr.
Temperature of 1st product 72°C ≤ 85°C
Picture 1
Picture 2
OFF Tare ON
10 mm
for 120gr and
superior
Ø max 2mm
17 mmfor 60gr
35 mm
for 35gr
Picture 3
DISPLAY