Philips EP Series
Process stap Saeco No. Action
Safety check
Earth leakage, Isolation test, resistor of earth wire grounding, as requested in certain country’s (VDE, ISO) or
H-POT TEST
Visual
Check the mains cord for damages
Packing
Packing
Check completeness (accessories) according income log refer #
Neatly pack the product
Documentation
Info for Consumer by packed ? e.g. service brochure, FAQ, NFF letter, s/c etc.…
Descaling instruction with changed procedure (S/C) if available
Repair report
Is there an answer to ALL consumer questions/complaints (see complaint)
add set statistic and give, if needed clear instruction towards consumer
Is it indicated which documents are added
Are there tips how to prevent issues
Error Codes
CODE Description Notes
Grinder fail ( grinder blocked )
Grinder fail ( grinder turns not detected)
Bu movement toward WORK fail
Bu movement toward HOME fail
Water circuit fail
NTC short circuit fail
NTC open circuit fail
Heater over-temperature fail
Heater time-out fail
Zero-Crossing fail
The error codes stored by the machine can be accessed via the USCP CONFIG MODE.
The information related to the error codes are available in the ErrorLog made up of 10 records.
The error codes are stored according to a FIFO concept.
The last error will be always at the rst position ErrorLog1. And the older ones will be shifted down every
time a new error code is added in the rst position.
Position Time Time Time Time … TimeN TimeN+
ErrorLog A G R C Z
ErrorLog A G B C
ErrorLog A R B
ErrorLog G R
ErrorLog H G
ErrorLog I H
ErrorLog O I
ErrorLog R O
ErrorLog G R
ErrorLog A G
Functions/features explanation