Philips EP Series
Process stap Saeco No. Action
Safety check
 Earth leakage, Isolation test, resistor of earth wire grounding, as requested in certain country’s (VDE, ISO) or
H-POT TEST
Visual
 Check the mains cord for damages
Packing
 Packing
 Check completeness (accessories) according income log refer #
 Neatly pack the product
Documentation
 Info for Consumer by packed ? e.g. service brochure, FAQ, NFF letter, s/c etc.…
 Descaling instruction with changed procedure (S/C) if available
Repair report
 Is there an answer to ALL consumer questions/complaints (see complaint)
 add set statistic and give, if needed clear instruction towards consumer
 Is it indicated which documents are added
 Are there tips how to prevent issues
Error Codes
CODE Description Notes
 Grinder fail ( grinder blocked )
 Grinder fail ( grinder turns not detected)
 Bu movement toward WORK fail
 Bu movement toward HOME fail
 Water circuit fail
 NTC short circuit fail
 NTC open circuit fail
 Heater over-temperature fail
 Heater time-out fail
 Zero-Crossing fail
The error codes stored by the machine can be accessed via the USCP CONFIG MODE.
The information related to the error codes are available in the ErrorLog made up of 10 records.
The error codes are stored according to a FIFO concept.
The last error will be always at the rst position ErrorLog1. And the older ones will be shifted down every
time a new error code is added in the rst position.
Position Time Time Time Time TimeN TimeN+
ErrorLog  A G R C Z
ErrorLog  A G B C
ErrorLog  A R B
ErrorLog  G R
ErrorLog  H G
ErrorLog  I H
ErrorLog  O I
ErrorLog  R O
ErrorLog  G R
ErrorLog  A G