. When assemby the nger-protection screw:
• Up to SN TW901907111749 use torque force 1.2Nm +/- 0.1
• From SN TW901907111750 use torque force 0.8Nm +/- 0.1
. Take out the two screws in the back panel and remove it.
. To remove the two laterals panel take out screws for each of them
Disassembly - and Reassembly advice