Level 2 (Loads and Sensors)
Start condition: NO BU, NO drag
drawer, Door open, No Water
UI/DISPLAY STATUS
Sequence of
actions by user
Reaction of the appliance
PASS FAIL Cause of failure Solution
Check the start
condition
• Lx OFF in UI panel +
• BoxT Red in Display
BoxT Red in Display
BoxT Green in Display
Water level sensor
damaged (short circuit)
Change Water
level sensor
Connector JP in
Main damaged (short
circuit)
Change Main
board
uP U in Main
damaged (short circuit
in Pin)
Change Main
board
BoxT Green in Display
L damaged Change UI boad
The Microswitch is not
well placed
Check assembly
of microswitch
Microswitch damaged
(short circuit)
Change
microswitch
Connector JP in
Main damaged (schort
circuit)
Change Main
board
uP U in Main
damaged (short circuit
in Pin)
Change Main
board
Insert BrewUnit
& Close Door (No
Dump Box)
No changes
BoxT Green in Display
Assembly issue of
the microswitch or
mechanical lever.
Check icroswitch
position and
mechanical lever.
Insert a full
water tank
• Lx OFF in UI panel +
BoxT remain Red in
Display
Water level sensor not
in position
Change the
position
of Water level
sensor
Water level sensor
damaged (open
circuit)
Change Water
level
sensor
Test mode