There are  dierent levels, in each level the coee-machine can execute dierent commands,
Level : In this level the operator can
. test all the Buttons and Leds activation and color:
a. Buttons : K, K, K, K, K, K, K, K, K, K, K, K, K, K, K.
b. Leds :L(W), L(W), L(W), L(W), L(W), L(W), L(W), L(R), L(G), L(B), L(W),
L(W), L(W), L(W), L(W), L(W), L(W), L(W), L(W).
. Check the version of the UI SW.
. Check the version of the Main SW.
. Check the version of the UI Boot.
. Check the version of the Main Boot.
. Check the frequency of the net ( Hz,  Hz).
. Check the voltage of the net ( V,  V).
. Check the buzzer sound.
Level : In this level the operator can:
. Test all the loads:
a. Move the Brew Unit upward and downward.
b. Open/Closed the EVs.
c. Start the Pump.
d. Start the Heater.
e. Start the Grinder.
. Test all the sensors:
a. Microswitch door activated/not activated.
b. Microswitch BU position (work/home) activated/not activated.
c. Hall sensor water level activated/not activated.
d. Flowmeter
e. NTC
. Execute special functions:
a. Steam-out (see dedicated documents).
b. execute the Reset to default (see dedicated document).
c. Reset of the Error log
d. Reset of the Grinder parameters.
The user can switch the level by pressing the Button K.
Legend:
(O) = Orange
(B) = Blu
(R) = Red
(G) = Green
(W) = White
At the start up all loads are turned o. The software allow to have multiple loads active at the same time.