Philips EP Series
Sequence of
actions by user
Reaction of the appliance
PASS FAIL Cause of failure Solution
Insert a full
water tank
BoxT Red in Display +
BoxT Green in Display
BoxT in Display change
BoxT remain Red in
Display
Wiring of the water
level sensor not
connected
Check the wiring
uP U in Main
damaged (open circuit
in Pin)
Change Main
Boad
Insert Dreg
drawer and rip
tray
Lx OFF in UI panel +
BoxT Green in Display +
BoxT Green in Display
BoxT in Display change
BoxT remain Red in
Display
The Microswitch is not
well placed
Check assembly
of microswitch
Microswitch damaged
(open circuit)
Change
microswitch
Wiring of the
microswicth not
connected
Check the wiring
Wiring of the
microswicth damaged
(open)
Change the wiring
uP U in Main
damaged (open circuit
in Pin)
Change Main
boad
Test mode