The following conditions are mandatory for the Steam Out procedure:
. The Ntc sensor must work correctly; if there is a failure on NTC (Ntc disconnected or in short
circuit) the operation cannot be performed (turn o the machine and repair before do Steam-out
operation).
. The DREGDRAWER must be in place and the DOOR must be closed; if someone is not in place the
operation cannot be performed. To start again the operation insert drag drawer and close service
door.
When the Steam-Out is complete the following parameters are reset to their default values:
Parameters Default Value Description Memory map
All recipes book See req. All recipes book restored to the default.
See _OmniaRecipes
N
Alarm_Rell TRUE Request priming circuit next power-on of the
machine
N
Bu_Loaded FALSE Set Brew-unit clean and not ll with coee N
Initial_Rinsing TRUE At the start up the machine will perform the
initial rinsing.
N
Temperature Medium The temperature in the setting will set to
Medium
N
First use TRUE At the start up the machine will request the rst
installation
N
Brightness of the display Medium The Brightness of the display is set in to
Medium
N
Unit ml The Unit is set to ml. N
Prole Active BLUE The Prole active is set to BLUE N
AquaClean reminder The AquaClean reminder is restored. N
Aroma Very Mild Time (ms)  Grinding time for aroma  (ms) Y
Aroma Mild/Medium Time
(ms)
 Grinding time for aroma  (ms) Y
Aroma Strong/ExtraStrong
Time (ms)
 Grinding time for aroma  (ms) Y
BU Unload Current Array [i]  Array of last  brew unit eort during rinsing
cycle (in milliamperes). → Autozero for new
autodose system. (i=..)
Y
Max Grinder Time (ms)  Maximum time for the grinder Y
Grinder Num Skip Adjust
Dose
Y
Array BU Pointer Pointer in the BU Unloaded current Y
Coee Grounds  Number of grounds in dregs drawer Y
AquaClean Filter
Autonomy (ml)
Autonomy of last Aqua clean lter activated Y
AquaClean Filter Startup
(ml)
 Counter of water for enable rst Aqua Clean
lter; if expire, the machine need a descaling
action to activate a new lter.
Y
AquaClean Actual Filter Number of Aqua clean lter active in aquaclean
chain
Y
Functions/features explanation

Related product manuals