PHI 5000 03 OPERATING LOGIC
3/8
When the coee grinder is working, the soware monitors the current consumption. If the current value is
very low, the machine concludes that coee is missing; if the current value is very high, the machine concludes
that the coee grinder is blocked; instead, if the current value is in the middle, the machine concludes that all
is ok and it goes on to do the product.
Because the current consumption of grinder changes depending on the situations (motor new or old, cold or
hot, coee blends, etc.), these current targets are not static, but dynamic.
3.5 Coee lack detection and coee grinder blocked
3.6. Coee cycle
Main switch ON START STOP
Time
Coee grinder
Heating
Pump
Brewing unit gear
motor
Status Heating Ready Coee cycle
Time
(Dosage)
Pump operation (ow
meter pulses) in
accordance with the
amount of product
selected.
approx.
45 sec.
*
Notes: * Only with Pre-brewing
Status
Microswitch
(gear motor)
OFF
ON
Coee cycle
1. e coee grinder starts the grinding process (controlled by Time);
2. e gear motor (brewing unit) moves to the brewing position;
3. Preliminary dispensing phase (short pump activity, short pause);
3.1. Solenoid valve opening (For products: Cappuccino and Frothed Milk);
3.2. Dispensing Milk (For products: Cappuccino and Frothed Milk);
3.3. Solenoid valve closing (For products: Cappuccino and Frothed Milk);
4. Coee dispensing (the pump operation period is dened by the amount of product dispensed);
5. e gear motor moves to its home position (the dregs are expelled automatically);
Note: For the product cafè au lait, the dispensing of the milk takes place aer that of coee.