PHI 5000 04 DIAGNOSTIC MODE
10/8
ERROR
CODES
DESCRIPTION
01
The coee grinder is blocked
02
The grinder is disconnected
03
The brewing unit is blocked in work position
04
The brewing unit is blocked in home position
05
The hydraulic circuit is clogged
10
The temperature sensor is in short circuit
11
The temperature sensor is opened
14
The temperature was up to 170°
15
The machine doesn’t heat up
19
The net is not stable
22
The keyboard is not recognized
4.4. Error codes
LastErrorLogged 0 Last error saved in machine
Gr_bu_uc_arr[jj] 150 Array of last 4 brew unit eort during rinsing cycle (in
milliamperes). Autozero for new autodose system
Gr_time_aroma[Light] 3000 Grinding time for aroma 1 (ms)
Gr_time_aroma[Medium] 3500 Grinding time for aroma 2 e aroma 3 (ms)
Gr_time_aroma[Strong] 4000 Grinding time for aroma 4 e aroma 5 (ms)
Coe_Duct_empty TRUE Set grinder conduct clean – used to increase
grinding time for rst grinding product next
power-on.
DebugGrinder FALSE If true machine enter in debug mode next
power-on.
Filter_autonomy 0 Autonomy of last Aqua clean lter actived
Filter_counter 0 Number of Aqua clean lter actived in aquaclean
chain
Filter_startup_qty 5000 Counter of water for enable rst Aqua Clean
lter; if expire, the machine need a descaling
action to activate a new lter.
InstallFilterRemind TRUE Request Aqua clean lter activation next poweron
FilterPulses 0 Impulses brew through Brita lter (not used in Incanto
Machine)