receive multiple and variable selcalls (used for sending status, etc)
G – Selcall Options 0 = none
1 = CCIR selcall
2 = ZVE 1 selcall
3 = EEA selcall
4 = EIA selcall
5 = No selcall with I/O expansion kit
6 = CCIR selcall, encode type 2
7 = ZVE selcall, encode type 2
8 = EEA selcall, encode type 2
9 = EIA selcall, encode type 2
Note that most selcall hybrids can only respond to CCIR selcall tones,
the other selcall modes were not well supported.
H – Other Options 0 = standard version
1 = reverse tone burst
2 = dual front end
3 = ignition noise blanker
Software Code made up of 15 Digits:
The software code for a FM92E with remote head for 6 Meters = 110404200000000
A – Channel Display 0 = intermittent display
1 = continuous display
2 = intermittent + 8 hour timer (auto power off)
3 = continuous display + 8 hour timer
B – Mute 0 = fixed, with defeat
1 = variable with defeat
2 = fixed, no defeat
3 = variable, no defeat
C – Economiser Options
D – Tx Timer 0 = Off
1 = 1 minute
2 = 3 minutes
3 = 5 minutes
4 = 10 minutes
E – Tx Inhibit 0 = Off
1 = Tx inhibit all channels
F – Tx power 0 = 25 watts
1 = 5 watts
2 = 1 watt
3 = Operator selectable
4 = per channel option
6 = 5-25 watts
7 = 1-25 watts adjustable
G – Scanning 0 = none
1 = scan vacant per programmed blocks
2 = scan occupied per programmed blocks
3 = scan occupied, operator selectable, per programmed blocks
Philips FM92E Conversion to 6 Meters: Version 3.9 Page 73
H – Voting 0
= No voting