Cleaning the lter
1 Take out the lter and the lter
support from the reservoir (g. m).
2 Remove the lter from the lter
support (g. n).
3 Soak the lter in tap water for one
hour (g. o).
4 Rinse the lter under a slowly
running tap water. (g. v).
5 Let excess water drip o the lter.
6 Assemble the lter around the lter
support (g. x).
7 Put the lter and the lter support
back into the reservoir (g. y).
8 Put the upper unit back onto the
reservoir (g. e).
Note
• Do not squeeze or wring the lter. This
might damage the lter and impact the
humidier’s performance.
• Do not dry the lter under direct
sunlight.
Removing scale
1 Switch o the humidier and unplug
from the electrical outlet.
2 Remove the upper unit by holding it
at both sides (g. c).
3 Remove lter and lter support from
the reservoir (g. m).
4 Empty reservoir.
5 Fill reservoir with 8oz./236.5ml
undiluted white vinegar. Let solution
sit in reservoir for 20 minutes
(g. p).
6 Clean all interior surfaces with
a soft brush. Dampen soft cloth
with undiluted white vinegar and
wipe out reservoir to remove scale
(g. q).
7 Rinse thoroughly with clean, warm
water to remove scale and cleaning
solution before disinfecting the
reservoir (g. r).
Disinfecting the reservoir
1 Follow the instructions for removing
scale.
2 Place reservoir in a sink. Fill reservoir
with a solution of 1 tsp/5g chlorine
bleach in 1 gal/3.78liters water. Let
solution stay 20 minutes, swishing
every few minutes. Wet all surfaces
(g. s).
3 Empty reservoir and rinse with water
until bleach smell is gone (g. t).
4 Dry the inside and outside of the
reservoir with a soft, clean cloth or
paper towel (g. u).
5 Put the lter and lter support back
into the reservoir (g. y).
6 Place the upper unit back onto the
reservoir (g. e).