Check the breast pump kit parts for wear or damage before use and replace them if necessary.
Note: Correct placement of the cushion, silicone diaphragm and silicone tube is essential for the
breast pump to form a proper vacuum.
1. Wash your hands
thoroughly with soap
and water.
2. Push the white valve
in the pump body as far
as possible.
3. Screw the pump body
onto the bottle.
4. Place the cushion
in the pump body and
make sure that the rim
covers the pump body.
4A. Push the inner part
of the cushion into
the funnel against the
line (indicated with an
arrow).
5. Place the silicone
diaphragm in the pump
body.
5A. Make sure that the
silicone diaphragm ts
securely around the rim
by pressing it down with
your thumbs.
6. Attach the silicone
tube and cap onto the
silicone diaphragm.
Push down the cap
until it is securely in
place.
7. Connect the tube(s)
to the motor unit.
8. Insert the adapter
into the wall socket and
insert the small plug at
the other end into the
motor unit.
9. The breast pump is
now ready for use.
Note: You can
place the cover over
the cushion to keep
the breast pump
clean when you take
it with you and while
you are preparing for
expressing.
English