After
replacing
the
roller
unit
(right),
the
tape path
has
to
be
checked,
and
adjusted
if
necessary
(paragraph
4.2.1).
4.1.9
Roller
unit
left
(Pos.23)
Set
the
drive
assy
to
,Eject’
position.
Unhook
the
tension
arm
spring
(pos.
11),
to
avoid
the
tension
arm
spring
being
pre-loaded.
At
the
bottom
side
of
the
drive
assy
remove
the
tension
lever
(pos.112).
Compress
the
two
snap
hooks
by
means
of
a
pair
of
tweezers
(Fig.
9)and
remove
the
roller
assy
(A)
from
the
plate
(B).
Unhinge
the
loading
arm
(left)
from
the
holding
plate
and
remove
the
latter
downward
from
the
drive
assy
through
the
recess
in
the
chassis
(Fig.
15).
The
reassembly
is
carried
out
in
reverse
order.
NOTE
:
During
reassembly
1.
Place
the
carriage
holding
plate
in
the
assembly
with
the
half-
round
cutout
nearest
the
rear
of
the
deck.
2.
When
the
loading
arm
is
refitted
ensure
the
pin
on
the
underside
of
23
is
through
the
link
of
24B.
After
replacing
the
roller
unit
(left)
the
tape
path
has
to
be
checked
(paragraph
4.2.1.),
and
adjusted
if
necessary.
fig.
15
4.2
Adjustments
Adjustments
must
not
be
made
in
the
service
position.
4.2.1
Tape
path
4.2.1.1
Roller
left
unit/roller
unit
right
Preparation:
Connect
one
input
of
a
duai
trace
oscilloscope
to
observe
the
tape
sync
pulse
CTL.
The
other
input
(DC
coupled)
to
observe
the
tracking
information
TRIV.
Trigger
the
oscilloscope
externally
on
the
head
pulse
HP1
(“SWIN’).
4-5
Playback
the
black
and
white
section
of
the
alignment
test
tape.
Set
the
deck
in
the
condition
where
the
video
heads
are
running
along
the
upper
edge
of
the
tracks
only
by:
1.
Call
the
service
test
program
(chapter
2.1)
2.
Activate
manual
tracking
(service
test
program
step
03)
and
watch
the
tape
sync
pulse
move
to
the
left
in
relation
to
the
TRIV
signal.
3.
Note
the
extreme
left
hand
position
reached
by
the
sync
pulse,
repeat
as
necessary.
4.
Stop
the
movement
of
the
pulse
when
the
TRIV
signal
reduces
to
1/2
to
2/3
maximum
amplitude
by
pressing
the
normal
play
button.
A
noisy
picture
(disturbances)
is
visible
on
the
TV
set
and
the
CTL
pulse
should
be
to
the
left
of
the
display.
The
recorder
will
hold
this
position
until
the
service
test
progam
step
03
is
left.
This
condition
works
only
if
X-distance
is
adjusted.
Picture
is
visible
trom
toil
side
fig.
18
Adjustment:
Adjust
the
left
and
right
roller
units
to
make
the
tracking
signal
TRIV
straight
and
flat
as
possible
(Fig.
18).
4.2.1.2
AIC
Combi
head
Tilt
angle
adjustment
Set
the
drive
to
feature
mode
(e.g.
+7)
Adjustment
:
Tape
guide
Capstan
wheel
(2)
rane
guide
(Reverse
lever)
Pressure
roller
GB