WelcomeEye Connect / Touch / 08/17
GB6
2. Conguring the intercom (see. 1, g. 2 and g. 3)
a. Conguring the intercom number:
Insert switch 2 in the left side of intercom panel n°1 and in the right side of intercom panel
n°2.
b. Conguring family name:
Insert switch 1 in the left side for single family mode and in the right side for double family
mode.
c. Setting the volume for the intercom:
Turn the volume control with a Phillips head screwdriver to adjust the intercom volume.
d. Conguring the RFID function:
1) Programming or resetting your administrator badges:
When turning the device on for the rst time, it is essential to congure the badges in the
following order:
1. Press the reset button at the back of the intercom panel for ve seconds, the intercom
will emit six short beeps.
2. Swipe the yellow administrator badge, one short beep conrms the programming.
3. Swipe the blue badge, one short beep conrms the programming.
4. Swipe the red badge, one long beep conrms that the administration badges have been
programmed.
2) Adding additional user badges
1. Swipe the blue badge, four long beeps conrm the activation of the programming mode.
2. Swipe all the grey user badges to be activated, one short beep conrms the activation of
each badge that is swiped.
3. When all of the badges are activated, wait for 10 seconds. One long beep conrms the
end of the programming process.
3) Removing additional user badges
1. Swipe the red badge, four long beeps conrm the activation of the programming mode.
2. Swipe all the grey user badges to be deactivated, one short beep conrms the deactivation
of each badge that is swiped.
3. When all of the badges have been deactivated, wait for 10 seconds. One long beep
conrms the end of the programming process.
4) Removing all user badges:
1. Swipe the yellow badge, four long beeps conrm the activation of the administration
mode.
2. Swipe one activated grey user badge, one short beep conrms that all user badges are
now deactivated.
5) Using the badges:
To open the electric strike plate, quickly swipe your pre-programmed grey user badge on
the RFID reading eld. One short beep conrms the opening of the electric strike plate.
To open the gate motor, hold the badge for three seconds against the RFID reading eld.
Two short beeps conrm the opening of the gate.