EasyManua.ls Logo

Phoenix Contact FL SWITCH 2008F - Page 211

Phoenix Contact FL SWITCH 2008F
228 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Technical data
108997_en_04 PHOENIX CONTACT 211 / 226
MAC address table 8k
MTTF 461.15 Years (SN29500 standard, temperature25°C,
operating cycle21%)
MTTF 149.69 Years (SN29500 standard, temperature40°C,
operating cycle34.25%)
MTTF 19.78 Years (SN29500 standard, temperature70°C, operating
cycle100%)
General data
Connection data
Connection method M12 connector (L-coded)
Interface: Ethernet
Number of interfaces 8
Connection method M12 connectors, X-coded
Note on the connection method Auto negotiation and autocrossing
Transmission physics Copper
Transmission speed 10/100/1000 Mbps
Transmission length 100 m (per segment)
Supply voltage
Supply voltage 24 VDC (redundant)
Residual ripple 3.6 V
PP
(within the permitted voltage range)
Supply voltage range 9 VDC ... 57 VDC
Typical current consumption 260 mA (at U
S
= 24VDC and 25°C ambient temperature)
Max. current consumption 0.77 A (U
S
= min, T
amb
= max)
Maximum power dissipation for nominal condition 6.93 W (U
S
= min, T
amb
= max)
Test section for one minute 500 VDC
Mechanical tests
Mechanical tests Free fall in accordance with EN61131-2
Vibration (operation) in acc. with IEC 60068-2-6: 5g, 150 Hz
Vibration (storage/transport) 5g, 150 Hz, in acc. with IEC 60068-2-6
Shock (operation) 30g (EN60068-2-27)
Conformity with EMC directives
Electromagnetic compatibility Conformance with EMC Directive 2014/30/EU
Conducted noise emission EN 61000-6-3 (conducted emissions) Class B
Interference emission EN 61000-6-3 (conducted emissions) Class B
Immunity to burst EN 61000-6-2 EN 61000-4-4 (EFT burst) Criterion A
Immunity to EF EN 61000-6-2 EN 61000-4-3 (electromagnetic fields) Criterion
A