Unifarm Machinery Corporation
PO Box 38, Wilson, NC, U.S.A.
page 17
picture 11 picture 12
picture 13 picture 14
The old oil must be disposed of in compliance with the local
laws where these activities are carried out; do not spill or
dispose of waste oil on the ground.
The maintenance activities must be carried out with the
engine off, the power take off disengaged, the parking brake
engaged, and the equipment placed on the ground.
BLADE REPLACEMENT
To assure the optimum efficiency of the machine, make sure that the tiller blades are in a good
working condition and that their bolts are tightened; replace them if they are broken or bent. The
new parts must be installed in the original position.
The T5, T10, T15, T20, T25, T30 tillers are equipped with 6 blades per flange; but it is possible to
reduce the number to four blades per flange (except for T25, T30 tillers), in case special ground