Type | PNOZ m EF 16DI |
---|---|
Number of safe inputs | 16 |
Input Voltage | 24 V DC |
Safety category | Category 4 |
Performance Level | PL e |
Communication Interface | PNOZmulti |
Connection type | Screw terminals |
Standards | EN ISO 13849-1, EN 62061 |
Specifies the intended application of the expansion module for safety-related interruption of safety circuits.
Covers safety assessment, qualified personnel, warranty, disposal, and general safety precautions.
Details the relay's safety criteria, including redundancy, self-monitoring, and failure effectiveness.
Provides guidelines for installing the unit in a control cabinet, mounting rail, and environmental considerations.
Explains how to connect the base unit and expansion modules, including terminator fitting and configuration.
Refers to PNOZmulti Configurator diagrams and specifies using copper wire rated for 75° C.
Presents safety characteristic data (SIL/PL) for logic CPU and various input types.