EasyManua.ls Logo

Pilz PSS 3032 - Example: Single-Channel, Failsafe Input Device, Unchecked

Pilz PSS 3032
45 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Connecting the Inputs and Outputs
5-6 Installation Manual: PSS 3032
Example: Single-channel, failsafe input device, unchecked
Features:
The input device must be approved for failsafe applications.
Please read the instructions provided with the input device.
CAUTION!
It will not be possible to detect a short circuit in the cable between the
input device/input and the L+ line, nor a short circuit between several input
devices. Depending on the type of input device connected, this could
create a risk to both personnel and machinery (e.g. emergency stop). You
should always ensure that the unit is suitably wired to eliminate the risk of
short circuits.