PNOZmc7p
OperatingManual1003050EN02
ConfigurableControlSystemPNOZmulti
Question and Answer IconNeed help?

Do you have a question about the Pilz PNOZmulti Series and is the answer not in the manual?

Pilz PNOZmulti Series Specifications

General IconGeneral
MountingDIN rail
Modular ExpandabilityYes
SeriesPNOZmulti
Number of Safety InputsConfigurable
Number of Safety OutputsConfigurable
Expansion ModulesYes
Communication InterfacesEthernet
ConfigurationSoftware-configurable
Safety StandardsEN ISO 13849-1, IEC 61508
SILSIL 3
PLPL e
Supply Voltage24 V DC
Operating Temperature-20 °C to +60 °C (depending on the module)

Summary

Safety

Intended Use

Specifies the PNOZ mc7p's application as a CC-Link expansion module for PNOZmulti safety circuits.

Safety Regulations and Precautions

Covers requirements for qualified personnel, warranty, disposal, and essential safety rules.

Function Description

Installation

General Installation Guidelines

Provides instructions for mounting, ventilation, earthing, and environmental considerations in control cabinets.

Connecting Base Unit and Expansion Modules

Guides on how to connect the PNOZ mc7p to the PNOZmulti base unit and other expansion modules.

Commissioning

General Wiring Guidelines

Covers wiring standards, copper wiring, earthing connections, and power supply requirements.

Interface Assignment

Details the CC-Link interface pinout and output communication assignments.

Download Modified Project

Instructions for updating the system project after adding an expansion module.

Operation

Technical Details