17
2.When LRN is not 0, DT SUM‟s CRC checksum is only related with DATA column, and
is not related to the prior 13 bytes, at this time, data package total length is (13+LEN+2)
byte.
3.High order is in front and the low order is in rear to multi-byte column.
2. Communication package format explanation:
3. .communication command:
Set communication baud rate
set measuring result sending frequency
start or stop preset tare device
The response of OP box(Command failure)
The response of OP box(Command success )
2)Command explanation:
4. Set communication baud rate:( Successful response 0x800E,Failure response 0x800D)
Default the baud rate is 9600bps when power on. When the command is received successfully, change
baud rate by parameter PARA1.
XX = 0x01 : 115200 bps
XX = 0x02 : 57600 bps
XX = 0x03 : 38400 bps
XX = 0x06 : 19200 bps
XX = 0x0C : 9600 bps
Command use method:PC use the default baud rate 9600bps to send this command to OP box firstly, and
then continue to use 9600bps baud rate to response after OP box received the command. Then switch the
Communications packet starting marks 0xAB
Parameter related with command
Data package number(single/last one fill with0)
The sum form item1to item6, total 12 bytes
Command data,Max 49 bytes