20
When receive the above data, it means: weight is stable, net weight weighing model, unit
kg, 3 decimal places, symbol is negative, -1.234 kg.
Flag
Mode
Unit
Decimal Digit
Net Value
0x00
0x00
0x00
0x00
0x00,0x00,0x04,0xD2
When receive the above data, it means: weight is unstable, net weight weighing model, unit
g, 0 decimal places, symbol is positive, 1234 g.
5) Protocol change
1. PC sends replacement protocol
STX
Cmd
ETX1
ETX2
0
12
3
4
STX1 bytefixed as 0x3C.
Cmd2 bytes, OS2passively sends communication protocol fixed as 0x41, 0x4C.
OS2 actively sends communication protocol fixed as 0x50, 0x42.
Pinnacle scale DigitOpBox protocol fixed as 0x44, 0x42.
ETX11 bytefixed as 0x3E.
ETX21 bytefixed as 0x09.