Electrical Outlet
Warning! Shock Hazard!
- Never plug in an appliance with more than a 5 amp rat-
ing into this outlet.
- Always keep outlet covered when not in use.
Maintenance
Use only original equipment replacement parts. The use of
alternate or third party components can cause unsafe
operating conditions, and will void your warranty.
We suggest following a maintenance schedule as follows:
Fuel/Fuel T
ank
- Flush every 200 hours of operation or as
needed. Do not use water to flush the tank. Use fresh 1-K
kerosene only.
Filters
- The Fuel Filter and Oil Filter should be cleaned at
least twice per heating season by rinsing it in clean 1-K
kerosene. Contaminated fuel could make this necessary
immediately (see Figure 9).
Fan Blades
- Warning! Never service heater while hot or
still connected to electrical source. The fan blades should
be cleaned at least once per heating season, depending
on conditions.
Remove all accumulated dust and dirt with a damp cloth,
taking care not to bend any of the fan blades. Be sure fan
blades are dry before re-starting the heater (Figure 10).
Nozzles
- Nozzles should be cleaned or replaced at least
once per heating season. Contaminated fuel could make
this necessary immediately.
To clean dirt from nozzle, blow compressed air through
nozzle front. It may be necessary to soak nozzle in clean
1-K kerosene to help loosen any particles (Figure 11).
S
park Plug - Clean and re-gap every 600 hours of opera-
tion, or replace as needed.
After removing the Spark Plug, clean the terminals with a
wire brush. Re-gap the terminals to 0.140” (3.5mm).
Figure 9. Filter Maintenance
Figure 11. Nozzle Maintenance
WARNING! NEVER SERVICE HEATER WHILE
HOT OR STILL CONNECTED TO ELECTRICAL
SOURCE.
Figure 8. Electric Outlet detail
NEVER LEAVE HEATER
UNATTENDED WHILE BURN-
ING, OR WHILE CONNECTED
TO A POWER SOURCE.
Ultra-Portable
Kerosene Heaters
Figure 12. Spark Plug Maintenance
Page 8 Pinnacle Products International, Inc. Ultra-Portable Kerosene Owners Manual
Figure 10. Fan Maintenance