DUCTLESS MINI SPLIT SYSTEM AIR CONDITIONER/HEAT PUMP
COMPACT CEILING CASSETTE
Installation
Manual
IMPORTANT NOTICE:
Please read this manual carefully before installing
or operating your new air conditioning system.
Be sure to save this manual for future reference.
CAB/CYB Series
CAB: Cooling-Only Version
CYB: Cooling and Heating Version
®
®
Inverter+ and Inverter++ Models
9,000-18,000 BTU/hr

Other manuals for Pioneer CYB Series

Question and Answer IconNeed help?

Do you have a question about the Pioneer CYB Series and is the answer not in the manual?

Pioneer CYB Series Specifications

General IconGeneral
TypeSplit System
Cooling Capacity (BTU/h)9000 - 36000
SEER RatingUp to 22
HSPF RatingUp to 10
Voltage (V)208/230
RefrigerantR410A
FeaturesInverter Technology
Dimensions (Indoor Unit)Varies by model
Dimensions (Outdoor Unit)Varies by model
Weight (Indoor Unit)Varies by model
Weight (Outdoor Unit)Varies by model

Summary

Safety Precautions

General Installation Safety and Guidelines

Read manual, use qualified personnel, follow NEC/CEC, installation instructions.

Electrical Safety and Grounding

Disconnect power, ground unit, use earth leakage breaker, proper wiring.

Refrigerant Handling and System Integrity

Prevent refrigerant leaks, avoid toxic gas, manage concentration, use correct parts.

Installation Information and Order

Manual Guidance and Personnel Requirements

Read manual first, installation by qualified persons only.

Key Installation Warnings

Avoid flammable materials, ensure unit stability, check for refrigerant leaks.

Indoor Unit Installation

Installation Area Hazards

Warnings against installing near flammable materials and risks of unit falling.

Outdoor Unit Installation

Refrigerant Pipe Installation

Pipe End Flaring Procedure

Cut, deburr, flare pipe ends using correct tools and torque.

Air Evacuation and Refrigerant Charging

Evacuation Procedure Steps

Connect manifold, vacuum pump, evacuate system to specified vacuum level.

Leak Check and Valve Operation

Perform leak check by monitoring vacuum, open/close service valves carefully.

Refrigerant Type Caution

Do not mix refrigerant types; use only R410a.

Electrical Wiring Work

General Wiring Instructions

Use licensed electrician, comply with regulations, follow wiring diagram.

Power Supply and Circuit Protection

Install circuit breaker, ensure proper grounding, avoid connecting to pipes/wires.

Wiring Connections and Precautions

Connect wires securely, avoid mixing gauges, prevent stress on terminals, seal gaps.