Description of Function Codes PE6000 User Manual
160
Group PC: Multi-Reference and Simple PLC Function
The PE6000 multi-reference has many functions. Besides multi-speed, it can be used as the
setting source of the V/F separated voltage source and setting source of process PID. In addition,
the multi-reference is relative value.
The simple PLC function is different from the PE6000 user programmable function. Simple PLC
can only complete simple combination of multi-reference, while the user programmable function is
more practical. For details, see the descriptions of group A7.
Function Code
Parameter Name Setting Range Default
PC-00 Reference 0 -100.0%–100.0% 0.0%
PC-01 Reference 1 -100.0%–100.0% 0.0%
PC-02 Reference 2 -100.0%–100.0% 0.0%
PC-03 Reference 3 -100.0%–100.0% 0.0%
PC-04 Reference 4 -100.0%–100.0% 0.0%
PC-05 Reference 5 -100.0%–100.0% 0.0%
PC-06 Reference 6 -100.0%–100.0% 0.0%
PC-07 Reference 7 -100.0%–100.0% 0.0%
PC-08 Reference 8 -100.0%–100.0% 0.0%
PC-09 Reference 9 -100.0%–100.0% 0.0%
PC-10 Reference 10 -100.0%–100.0% 0.0%
PC-11 Reference 11 -100.0%–100.0% 0.0%
PC-12 Reference 12 -100.0%–100.0% 0.0%
PC-13 Reference 13 -100.0%–100.0% 0.0%
PC-14 Reference 14 -100.0%–100.0% 0.0%
PC-15 Reference 15 -100.0%–100.0% 0.0%
Multi-reference can be the setting source of frequency, V/F separated voltage and process
PID.
The multi-reference is relative value and ranges from -100.0% to 100.0%.
As frequency source, it is a percentage relative to the maximum frequency. As V/F separated
voltage source, it is a percentage relative to the rated motor voltage. As process PID setting
source, it does not require conversion.