EasyManuals Logo

Pioneer PRO-1410HD User Manual

Pioneer PRO-1410HD
84 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #18 background imageLoading...
Page #18 background image
(5) Lighting in green, and then in red (Alarm of power voltage error)
Unlike [lighting in red] in the STANDBY mode, [lighting in green] continues for about 30 seconds without any
output of images and audio signals. Since then, the mode turns into [lighting in red].
YES
YES
When the main power supply is turned on in
the state that the AD, PD, and PH
connectors are disconnected, are there the
Vs (170Vdc) and Vd (60Vdc) outputs at Pins
- to Pins - of the PD connector and
a 5Vdc output at Pins - of the PH
connector? In this case, is the LED not
turned in red after it has been lit in green for
about 30 seconds? At that time, however, no
ima
ges are generated.
Test PDP Module Area.
NO
NO
NO
(Caution) How to reset the alarming condition The
alarming condition can be reset when an
OFF ON setting is repeated twice for the
main power supply in the state that the
LED is lit in red. The interval between the
first and second settings is not particularly
specified.
Lighting in red
Normal
NO
YES
The MAIN PWB or the
AUDIO PWB is fault.
The Power unit or the
PN connector is fault.
(Caution) The voltage values of Vd and Vs
can differ according to the PDP.
The method of checking these
voltage values is obtainable from
[2. Adjustment of the power unit]
in the method of adjustment.
YES
The MAIN PWB is fault.
Make an OFF ON setting
twice for the main power
supply in order to reset the
alarming condition.
Is the LED lit in red after it
has been lit in green for about
30 seconds?
When the main power supply is turned on in
the state that the PA and PV connectors are
disconnected from one after another, is
there a 12Vdc output at Pins - of the PA
connector or the 12Vdc and 6Vdc outputs at
Pins and - of the PV connector? In
this case, is the LED not turned in red after it
has been lit in green for about 30 seconds?
Is there an output of 3.3Vdc available at Pins
~ and 2.5Vdc at Pins ~ in the  
state that the PA and PV connectors are
returned to the former state, the main power
is turned ON, and the PN connector is
disconnected? In this case, however, this
check must be finished in 30 seconds.
Otherwise, there will be power tripping on
account of an alarm.