ALPHA Electro
www.pipistrel-aircraft.com
REV. 0
POH-167-00-40-150
1-4
General
Propulsion system
WARNING! The motor is not certified for aviation use, therefore, there is no assurance it
won’t fail during operation at any given moment, without prior notice.
Motor
TEMPERATURE °C PEM 60MVLC
Maximum takeoff power (1 min) 56 kW
Maximum continuous power 50 kW
Maximum operating temperature 90° C
Maximum ambient temperature 40° C
RPM PEM 60MVLC
Maximum allowable rpm 2500
Takeoff RPM (typical) 2400
Climb RPM (typical) 2250
Power controller
POWER CONTROLLER H300A
Nominal power 60 kW
Maximum operating temperature 65 °C
Maximum ambient temperature 40 °C
WARNING! Do not, under any circumstances, attempt to use any other batteries other than
Pipistrel factory-supplied batteries. Only use them with the motor and power controller men-
tioned in this POH.
Battery system
Battery system PB345V105E-A
Maximum voltage 398 V
Minimum voltage 288 V
Recommended voltage range for storage 355 V - 365 V
Maximum operating temperature 55° C
Minimum operating temperature 5° C
Allowable temperature range for storage 10 °C - 40 °C
Minimum charging temperature 0 °C
Maximum battery temperature before takeoff 40 °C
CAUTION! Temperatures below 10°c will cause a decrease in battery capacity. Plan your flight
accordingly.
WARNING! Do not, under any circumstances, attempt to charge the batteries with any third
party chargers. Only Pipistrel original equipment must be used.
WARNING! Respect operating and storage temperature limits at all times. Failure to do so
may result in battery damage.