ALPHA Electro
www.pipistrel-aircraft.com
REV. 0
POH-167-00-40-150
Kinds of operations
ALPHA Electro can be used for DAY - VFR operations only.
Flight into known icing conditions is prohibited.
WARNING! Should you find water drops on the airframe during pre-flight check-up at
temperatures close to freezing, you may expect icing to appear in flight.
Minimum equipment list (DAY - VFR)
•
Placards, checklist, this POH
•
Airspeed indicator (functional), Altimeter (functional), Compass (functional)
•
EPSI570
•
Both battery packs (functional), Safety belts (2x)
Energy limitations
Description: 2 metal boxes(packs) which include battery cells,
BMS and communication modules,
power and signal connectors
Total battery capacity: 21.0 kWh
Useful bat. capacity: 20.0 kWh
Maximum allowed output power with one battery pack connected 35 kW
NOTE The system will function with only one of the battery packs connected, however, the
power output must be kept below 35 kW.
WARNING! Takeoff is prohibited with a SOC (state of charge) below 40%.
2-6
Limitations