ALPHA Electro
www.pipistrel-aircraft.com
REV. 0
POH-167-00-40-150
POWER LEVER section
Power lever
Parameter Description
Presence: yes/no: On-line status of the component
Output: Value (0 to 1000) depending on the linear power position
Scaled:
Value (0 to 1000) - software scaled and adapted output value using a
xed map for the conversion. The relationship between output and
scaled values can‘t be modied by the operator
Final:
Power controller nal value (-300 to 1000). It takes the recuperation
contribution into account
Seen zero:
yes/no: shows if the power lever has been moved to cut o after
battery activation This is a safety feature. The motor can only be
started once power lever has been moved to cut o.
Warning and Caution Messages
System or component malfunctions, warnings and errors are shown in the central part of the display
when in FLIGHT mode. It is possible to reset the warning and error messages by pressing the knob. The
warning and error messages are “descriptive”, and give a basic description of the problem and/or system
affected.
NOTE See EPSI570 user action guide in Emergency procedures section of this manual for a com-
plete list of system warnings and cautions that can appear on the EPSI570 during operation.
9-8
Appendix