Technical characteristics Operating Instructions MSA 2 CF
26
6 Technical characteristics
Mains voltage and
frequency
115 V (100V÷130V) 50/60 Hz
Suggested power
generators
3.5kW
Welding technique Voltage controlled
Fusion voltage 3.6÷42V
Operating temperature 0°F / +120°F (-20°C / + 50°C)
Temperature sensor
resolution
± 1.8°F (±1 °C)
Fittings range Ø20mm ÷ 450mm (inner
diameter)
Fusion data input mode Bar code, manual
Capacity of internal memory 1000 records
USB Port Type A
Protection factor IP 65
Dimensions 280x280x420 mm (max)
Weight 26.5 pounds (12.8 Kg)
6.1 Standards
ISO 12176-2
ISO 12176-3
ISO 13950
CSA 22.2