DIAGNOSTIC CODES
CONDITION SPN FMI
Ignition Coil Primary Driver 3 Driver Circuit Short to B+ 1270 3
Cylinder 4 Misfire Detected 65594 7
O2 Sensor Circuit High Voltage Bank 1 Sensor 1 3056 3
ECU Output Supply Voltage 1 Voltage Above Warning
Level
3597 16
All Wheel Drive Control Circuit Driver Circuit Short to B+ 520207 3
Accelerator Sensor Synchronicity Fault - Sensor
Difference Exceeds Limit Condition Exists
520308 31
Throttle Body Control - Limp Home Position Check
Failed Condition Exists
520280 31
Throttle Position Sensor Neither Position Sensor
Passed Test
520276 12
Function Monitoring MoFTrq Comparison Error 520385 31
Throttle Body Control - Mechanical Stop Adptation
Failure Condition Exists
520281 31
RBA Monitoring Error Memory Read/Write 520383 31
ECU ADC Fault - No Load Condition Exists 520306 31
EVAP System Purge Control Valve "A" Circuit Shorted 520202 4
Chassis Relay Driver Circuit Short to B+ 520208 3
ETC Accelerator Position Sensor Outputs 1 & 2
Correlation. Correlation Fault
65613 2
Cylinder 3 Injector "A" Circuit Low 653 5
All Wheel Drive Control Circuit Driver Circuit Open/
Grounded
520207 5
ECU Output Supply Voltage 1 Voltage Below Warning
Level
3597 18
Cylinder 2 Misfire Detected 65592 7
Ignition Coil Primary Driver 4 Driver Circuit Short to B+ 1271 3
163
TROUBLESHOOTING

Other manuals for Polaris RZR Pro R 2022

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Polaris RZR Pro R 2022 and is the answer not in the manual?

Polaris RZR Pro R 2022 Specifications

General IconGeneral
BrandPolaris
ModelRZR Pro R 2022
CategoryOffroad Vehicle
LanguageEnglish

Related product manuals