EasyManuals Logo

Polaris RZR PRO XP 2020 User Manual

Polaris RZR PRO XP 2020
598 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #58 background imageLoading...
Page #58 background image
1.52
9850068 R01 - 2020-2021 RZR PRO XP / XP 4 Service Manual
© Copyright Polaris Industries Inc.
SPN COMPONENT
FMI CONDITION CODE
5 Current Below Normal Or Open Circuit P0481
1809 Lateral Acceleration Sensor
13 Out Of Calibration C1261
19 Received Network Data In Error U25CA
20 Data Drifted High C1161
1810
Longitudinal Acceleration Sensor
7 Mechanical System Not Responding Or Out Of Adjustment C1362
13 Out Of Calibration C1262
19 Received Network Data In Error U25CB
20 Data Drifted High C1162
1888 PTO Solenoid Driver Circuit
3 Voltage Above Normal, Or Shorted To High Source P1311
4 Voltage Below Normal, Or Shorted To Low Source P1312
5 Current Below Normal Or Open Circuit P1310
2584 Brake Pressure Switches
3 Voltage Above Normal, Or Shorted To High Source C2244
4 Voltage Below Normal, Or Shorted To Low Source C2044
13 Out Of Calibration C1263
17 Data Valid But Below Normal Operating Range - Least Severe Level C2144
20 Data Drifted High C1164
2590
Vehicle Speed
16 Data Valid But Above Normal Operating Range - Moderately Severe
Level
P1500
2596
Speed Key Selected Maximum
Vehicle Speed Limit Message
19 Received Network Data In Error U255A
31 Condition Exists U2259
2629
Engine Turbocharger 1
Compressor Outlet Temperature
3 Voltage Above Normal, Or Shorted To High Source P1235
4 Voltage Below Normal, Or Shorted To Low Source P1236
3056
Oxygen Sensor Bank 1 Sensor 1
2 Data Erratic, Intermittent Or Incorrect P0130
3 Voltage Above Normal, Or Shorted To High Source P0132
4 Voltage Below Normal, Or Shorted To Low Source P0131 / C1049
12 Bad Intelligent Device Or Component P113A
17 Data Valid But Below Normal Operating Range - Least Severe Level C2049
3057
Oxygen Sensor Bank 1 Sensor 2
2 Data Erratic, Intermittent Or Incorrect P0136
3 Voltage Above Normal, Or Shorted To High Source P0138
4 Voltage Below Normal, Or Shorted To Low Source P0137
3597
ECU Output Supply Voltage 1
0 Data Valid But Above Normal Operational Range - Most Severe Level P16A3
1 Data Valid But Below Normal Operational Range - Most Severe Level P16A6
3 Voltage Above Normal, Or Shorted To High Source P16A2
4 Voltage Below Normal, Or Shorted To Low Source P16A1
16 Data Valid But Above Normal Operating Range - Moderately Severe
Level
P16A5
18 Data Valid But Below Normal Operating Range - Moderately Severe
Level
P16A7
3598
ECU Output Supply Voltage 2
0 Data Valid But Above Normal Operational Range - Most Severe Level P16AA
1 Data Valid But Below Normal Operational Range - Most Severe Level P16AC
3 Voltage Above Normal, Or Shorted To High Source P16A9
4 Voltage Below Normal, Or Shorted To Low Source P16A8
16 Data Valid But Above Normal Operating Range - Moderately Severe
Level
P16AB
18 Data Valid But Below Normal Operating Range - Moderately Severe
Level
P16AD
3599
ECU Output Supply Voltage 3
0 Data Valid But Above Normal Operational Range - Most Severe Level P17AC
1 Data Valid But Below Normal Operational Range - Most Severe Level P17AE
3 Voltage Above Normal, Or Shorted To High Source P17AA
4 Voltage Below Normal, Or Shorted To Low Source P17AB
GENERAL INFORMATION

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Polaris RZR PRO XP 2020 and is the answer not in the manual?

Polaris RZR PRO XP 2020 Specifications

General IconGeneral
BrandPolaris
ModelRZR PRO XP 2020
CategoryOffroad Vehicle
LanguageEnglish

Related product manuals