THREE CYLINDER IGNITION (Con't.)
between the
lead
wire (white) and minus terminal
of
the
tester.
(3)
If
resistance
is
co
when connected inversely
to
the
above, the
lead
wire (black)
to
the minus
of
the tester and
the
lead
wire (white)
to
the plus
side.
(
4)
If
resistance
is
1-1OM
ohm when connected the
lead
wire (black
with
white stripes)
to
the plus,
and
the
lead
wire (red) and (white)
to
the minus.
(5)
If
resistance
is
10M ohm
or
more when connected
lead
wire (black
with
white stripes)
to
the plus,
and
the
lead
wire (black)
to
the minus.
(6)
If
a pointer
of
tester swings once
and
then
resets
when connected the
lead
wire (black
with
white stripe)
to
the plus,
and
the
lead
wire (orange)
to
the minus.
(7)
If
current flows when connected the
lead
wire (green)
to
the plus, and the
lead
wire (blue)
to
the minus.
(8)
If
resistance
is
oo
when inversely connected
to
the
above: the
lead
wire (green)
to
the minus, and the
lead
wire (blue)
to
the plus.
When
it
is
confirmed
that
the
unit
satisfies all
of
the above
checking items,
it
shows
that
the
unit
is
in normal con-
dition.
Next, clean dust
of
couplers and check its con-
dition. (In the above checking instructions, the plus