INSTALLATION
VORTEX EF2241 Reference Manual 12 Technical Support: 800.932.2774
whichever preset you want to come up after power up). The unit will need to be con-
figured for your system.
PROGRAM PARAMETERS FACTORY DEFAULT PRESET VALUE
SYSTEM PARAMETERS
Preset 0
Device ID 0
AUTOMIX PARAMETERS
Chairman Mode Off
Decay Time 1000 ms
Hold Time 500 ms
Last Mic On Mode On (on Automixer 1)
Max NOM per Automixer 4
Off Attenuation -15 dB
INPUT CHANNELS
Acoustic Echo Cancellation On
Automatic Gain Control (AGC) On
AGC Rate 1 dB/s
AGC Max Gain 3 dB
AGC Min Gain -3 dB
Automixer 1
Echo Canceller Reference Ref1
Filtering Off
Gate Priority 1
Adaptive Threshold 10 dB
Gate Threshold Adaptive
Gating Auto