EasyManua.ls Logo

POLYPOOL PP1465 - Page 3

POLYPOOL PP1465
20 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Temperature
set
Flat
battery
Boiler
operational
Clock
Manual
control
indicator
Program
number set
Ambient
temperature
The thermostat ignition sensitivity can be
selected: ± 0.2°C (factory setting, recommended
for heating systems with radiator) or + 0/-0.2°C (this
setting is recommended for underoor heating).
This conguration represents the temperature
dierence between the adjusted value and the actual
temperature measured during the ignition process.
For example, if the factory setting is 20°C on the
thermostat, the device turns on the boiler at 19.8°C
or below this level and goes o at 20.2°C or above.
(Please refer to section 3.3 for the change of ignition
sensitivity from factory default of ± 0.2°C).
The thermostat is equipped with a pump protection
function which, in order to prevent the pump
from blocking, turns on the boiler for one minute
at 24 every day if the pump has not turned on in a
programmed way for more than 24 hours (for example
, outside the heating season). See the activation of the
pump protection function in Section 3.4.
Information shown on the LCD
display of the thermostat:
Manual
timer
control
indicator
Days
week