Automatic boiler for pellets – User manual
3
Dear customer,
please, accept our congratulations to your decision to purchase this product and secure HEATING OF YOUR HOME
by burning renewable sources of energy, in this case WOODEN PELLETS.
You have shown exemplary personal responsibility for healthy environment for your children and future
generations in general.
Do believe that we had the same responsibility and approach while developing this product and we are convinced
that it will serve you well.
Please, pay attention to this OPERATING MANUAL to ensure proper operating of this product, which is vital for a
long-term service life of this product and your full satisfaction.
The boilers have been approved for operation in the Czech Republic and in 27 EU countries by the
State Testing Institute Brno, state testing laboratory no. 202. Manufacturer: PONAST spol. s.r.o., Na
Potůčkách 163, 757 01 Valašské Meziříčí, Czech Republic
tel.: +420 571 688 111 , fax +420 571 688 115, e-mail: ponast@ponast.cz. www. ponast@cz
1 IMPORTANT NOTIFICATIONS
- This product may be put into operation only by service organization trained by the manufacturer.
- It can be operated only by adults who are fully familiar with its control mechanisms and with this
manual.
- If you follow the guidelines below, our product will serve you reliably and to your full satisfaction.
1) It is forbidden to interfere with the construction or el. installation of the products.
2) To disconnect the device from the mains, it is necessary to unplug its power cord from the power
outlet!!!
3) It is forbidden to use flammable liquids for ignition.
4) It is forbidden to store any flammable materials on the boiler and within 1500 mm from the boiler (except
for the fuel supply stored in a metal hand carrier)
5) It is not recommended to frequently operate the boiler below 60°C to ensure long-term service life of the
boiler body.
6) If there is any work in the boiler room during which flammable vapours are generated (gluing the floor
etc.), the boiler has to be put out of order and burned out.
7) The Boiler door always has to be tightly closed.
It is FORBIDDEN to open the door when automatic
processes are in progress. During an inspection, open the door carefully, so you are not endangered by
possibly accumulated products of combustion and to prevent sparks flying out and cause an accident.
Open the door slowly, so aeration of the combustion chamber towards the chimney is possible. It is
necessary to proceed in the same manner when removing ash from the ashtray area.
8) After the heating season is over, clean the boiler thoroughly according to the instructions in the
Maintenance section. Residues of the products of combustion on the walls of the exchanger can cause
corrosion for the entire time the boiler is put out of operation. If the burner is not cleaned, this may have
an effect on imperfect burning. We recommend to have a specialized company to do the work.
9) Ensure that the device is safely disconnected from the mains when working on or near mechanical moving
parts (fuel feeders etc.) There is an accident hazard.
10) Always operate the boiler only within the parameter and according to the recommendations given by this
manual.
11) The manufacturer does not take any liability for any faults and consequent damage caused by
incompetent operation of the device or by breach of the guidelines given in this manual or by violating
generally valid standards and provisions or by using inadequate fuel.
12) When the boiler is moved or handled with, always follow the safety regulations and rules applied for
handling heavy loads.
13) It is forbidden to place heavy objects on top of the boiler or to step on it. It is recommended to remove
the protective plastic wrap after all the construction and assembling procedures are finished.