PUMP PROTECTION ACTIVE
The system has detected a low flow condition for longer than the time specified in the
PUMP PROTECTION TIME setting. The pump has been turned off, and will not restart
until the filtration mode is changed manually.
– Press the MODE button to toggle the filtration mode back to AUTO or ON.
– Refer to LOW FLOW recommendations below.
LOW FLOW
The system has detected a low flow condition, and will not be producing any chlorine.
– Check visually for water flowing through the cell. An air or gas pocket at the top of
the cell housing indicates that there is not enough flow.
– Inspect the cell for debris or calcium scale
– Check skimmer baskets and pump baskets, empty them if required.
– Backwash the filter if necessary - (sand filters only)
– Clean the filter cartridge(s) if necessary – (cartridge filters only)
– Check all valve positions are correct.
SPA FLOW DETECTED
The system has detected spa flow. Chlorine production will be halted to prevent over
chlorination of the spa.
DEFAULTS USED
The system could not read valid user settings from EEPROM memory, therefore factory
default settings have been loaded. It is normal for this to occur on a new unit at initial
power up, or after a memory reset. Otherwise it could indicate that the memory was
somehow corrupted, for example if power was cut whilst a changed setting was being
saved to memory. Although it would be extremely rare for this to occur.
MEMORY FAULT
The system could not successfully write to and read back from the internal memory. This
generally indicates a major fault with the PCB, and it is likely that user settings, timers,
running modes, etc. may not be able to be saved. Operation of the unit could be
unpredictable. Try to cycle power to the unit off, and back on again. If the problem
persists – return the unit for service.