- 41 -
Normal Code 39:
In this mode the decoded data characters are transmitted without further translation.
Full ASCII Code 39:
In this mode the decoded data characters are translated to full ASCII Code 39.
Full ASCII Code 39 if possible:
In this mode the decoded data characters are translated to full ASCII Code 39. Invalid
combinations are not translated and are transmitted as is.
Italian Pharmaceutical only:
In this mode the decoded data characters are translated to the Italian Pharmaceutical
format. If the data does not comply with the Italian Pharmaceutical format, the label is
rejected.
Italian Pharmaceutical if possible:
In this mode the decoded data characters are translated to the Italian Pharmaceutical
format. If the data does not comply with the Italian Pharmaceutical format, then the
data is transmitted as Normal or full ASCII Code 39.
Tri-Optic:
This fixed length symbology builds its data out of two data triplets, where the second
triplet is encoded at first. The following characters are supported:
the digits 0 up to 9
the upper case characters A up to Z
the characters - . / + % SPACE
start/stop character is $
For string format see figure 3.22.
There are no options for Tri-Optic supported.
Concatenation:
If a Code 39 bar code contains a leading space, the data is stored into the reader's
buffer without the leading space. As soon as a Code 39 bar code is read without a
leading space, the data is appended to the reader's buffer and the entire buffer is
transmitted and cleared for new data. In case a non Code 39 bar code is read, the data
in the non-Code 39 bar code is transmitted and the buffer is cleared. The buffer size is
reader dependent.